ctrlX I/O 2-channel analog input terminal for thermocouples (TC)

Product Description

The XI361002 temperature measurement module reads in temperatures from thermocouples (TC) on two independent channels. The module supports common sensor types such as K, J, T as well as various others and has an internal cold junction compensation (CJC) that can be switched off. Error states are shown at the status LED of the module and routed to the control via the local bus. The logic and peripheral voltage supply as well as the EtherCAT-based module communication are routed through the module.

Technical Specs

Product attributes

EPLAN

https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.XI361002**&downloads=true

Connection type

Push-in

Connectivity technology

2-wire technique, shielded, twisted in pairs

Number of channels

2

Width [mm]

12

Height [mm]

105

Depth [mm]

99

International protection code

IP20

Protection class

III

Backplane-Bus

Standard-EtherCAT über LVDS

Resolution A/D

16 Bit

EMC resistance

EN 61000-6-2 and EN 61000-6-4

Bit width, input data in the process data image (including fill bits)

10 bytes

A/D conversion time

240 ms for 1 channel; 480 ms for 2 channels

Maximum power dissipation in the module [W]

1.2

Post-assembly position

Vertical, on a horizontal support rail

Electrical isolation

1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL)

Supported sensor types

B, E, J, K, L, N, R, S, T, U

Current requirement UL

36 mA

Current requirement Up

12 mA

Nominal voltage (UL/UP)

DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage)

Overvoltage category

2

Signal type

Differential

Conductor cross-section

rigid: 0.2-1.5 mm²,Flexible: 0.2-1.5 mm²,AWG: 24 ... 16

Overload protection

9.9 V

Permissible air humidity (storage) [%]

10-95

Permissible air humidity (transport) [%]

10-95

Ambient temperature (storage and transport) [°C]

-40-70

Ambient temperature during operation

Up to 2000 m: -25°C to +45°C,2,000 m to 3,000 m: -25 °C to +40 °C

Maximum operating altitude [m]

3000

Contamination level

2, no condensation

Weight [kg]

0.11