г.Минск, ул.Бирюзова, д.4/5
Продажа подшипников в Минске и по всей Беларуси
Корзина
0 руб.

FIELD BUS MODULE XB-EC-12 [R911406090]

FIELD BUS MODULE XB-EC-12 [R911406090]
(0)
Нет в наличии
REXROTH
0 руб.
До конца акции осталось:
00дн.
00час.
00мин.
Подарок при покупке
Дарим подарок при покупке данного товара
Выбрать подарок

FIELD BUS MODULE XB-EC-12 [R911406090]
FIELD BUS MODULE XB-EC-12 [R911406090]
(0)
Нет в наличии
0 руб.


ctrlX I/O EtherCAT bus coupler

Product Description

The bus coupler XB-EC-12 connects the EtherCAT network and the ctrlX I\/O system.
It supplies the connected I\/O modules with the logic voltage UL and peripheral voltage UP. The voltages and currents fed in are measured internally and applied to the process data.
For the integration into the parent system, the respective ESI files are available. These files are available for download at www.boschrexroth.com\/electrics.

Technical Specs

Product attributes

EPLAN

https://ecad-configuration.boschrexroth.com/?rootpartnr=BOS.XB-EC-12**&downloads=true

Connection type

Push-in

Width [mm]

23.3

Height [mm]

105

Depth [mm]

99

International protection code

IP20

Protection class

III

Backplane-Bus

Standard-EtherCAT über LVDS

EMC resistance

EN 61000-6-2 and EN 61000-6-4

Bit width, input data in the process data image (including fill bits)

10 bytes

Maximum power dissipation in the module [W]

2.64

Inverse polarity protection up to [V]

50

Channel LEDs

Display status of Power supply

Post-assembly position

Vertical, on a horizontal support rail

Electrical isolation

1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL)

Fuse protection (UP)

No internal fuse protection. The operator has to provide protection against overload by an external fuse.

Fuse protection (UL)

Internal with a protective fuse

Transient protection

Present, suppressor diodes, pulse load up to 1500 W

Maximum number of modules per station

30

Power input UP

Typ. 0.12 W (without I/O modules), 192 W max. (complete system with I/O modules)

Power input UL

1.64 W max. (without I/O modules), 72 W max. (complete system with I/O modules)

Current requirement UL

Max. 60 mA (without I/O modules), 3 A max. (complete system with I/O modules)

Current requirement Up

Typ. 7 mA (without I/O modules), 8 A max. (complete system with I/O modules)

Nominal voltage (UL/UP)

DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage)

Overvoltage category

2

Voltage dips at power supply interfaces

PS1 <1 ms, evaluation criterion A

Overvoltage protection UL and UP

Present, fuses can trigger in case of overvoltage

Supply voltage LEDs

At the connection point to signal the applied voltage

Conductor cross-section

rigid: 0.75-1.5 mm²,Flexible: 0.75-1.5 mm²,AWG: 18 ... 16

Permissible air humidity (storage) [%]

10-95

Permissible air humidity (transport) [%]

10-95

Ambient temperature (storage and transport) [°C]

-40-70

Ambient temperature during operation

Up to 2,000 m: -25 °C to +55 °C,2,000 m to 3,000 m: -25 °C to +50 °C,3,000 m to 4,000 m: -25 °C to +45 °C,4,000 m to 5,000 m: -25 °C to +40 °C

Maximum operating altitude [m]

5000

Contamination level

2, no condensation

Weight [kg]

0.19

Мы стараемся максимально лояльно подходить к выбору способов доставки товаров из нашего магазина, чтобы наши клиенты получали необходимое качество по наименьшей цене.

Курьером по городу

Курьером (пн-пт). Курьер доставит товар в день заказа с 18 до 21.00 (при условии, что заказ сформирован до 18.00), либо вечером следующего дня (если заказ сформирован после 18.00).

Самовывозом

Вы можете забрать заказанный на сайте товар в любой день и удобное Вам время. Часы работы и контактный телефон магазина можно узнать здесь. Забронированный товар будет дожидаться Вас в течении двух рабочих дней.

Персональные рекомендации